AI Voice Analysis

AI Voice Analysis

Read naturally or hold a comfortable note. Keep the same microphone, distance and gain when comparing takes.

Microphone off0.0 s measured
Detected fundamental · Hz—
Digital RMS · dBFS—
Spectral centroid · Hz—

Up to 20 MB / 120 seconds. Codecs depend on browser support. Choose a short solo voice sample; music, noise, effects and microphone processing can alter results. Audio stays local. Stereo channels are averaged; opposite phases can cancel.

No file selected.

Input and analysis method

Fundamental detection50–1,500 Hz; Hann-windowed4,096-point spectrum. Spectral centroid is a magnitude-weighted frequency, not a measure of warmth or talent. Periodicity is the detector's normalized autocorrelation on detected frames, not clarity, intelligibility or clinical HNR. Levels are relative digital dBFS, not acoustic SPL. No recording or upload occurs during live measurement.

Held-note consistency is an app-defined0–10 practice score:60% × max(0,1−median absolute pitch deviation/100 cents),30% × voiced time fraction,10% × (1−clipping-frame fraction). Requires 3 voiced seconds; natural vibrato can lower it. It is not overall singing quality, attractiveness, vocal health or a professional rating. Speech has no quality score.

This tool uses local signal processing. It does not run a machine-learning model or an AI voice judge.

Ready when you are.

Related tools

  • Voice Hz Test — Understand retained fundamental-frequency statistics in a short sample.
  • Pitch Accuracy Test — Compare vocal production with known targets and distinguish score definitions.
  • Vocal Range Test — Find comfortable singing endpoints and choose the next appropriate task.

This AI Voice Analysis page measures selected acoustic features from a microphone sample or supported local recording. The current tool uses local signal processing, not a trained machine-learning model. It reports pitch, spectral balance and digital level, with an optional custom held-note consistency score.

If you are looking for an AI voice rater or a judgment of your singing, keep the scope clear: these are measurements of a sample. The tool does not understand lyrics, recognize a singer or grade expression, rhythm and overall performance.

Choose a task before analyzing

  1. Select Natural speech or One comfortable held note.
  2. Choose a 10, 20 or 30-second microphone window, or select a local file.
  3. Keep microphone distance and gain consistent.
  4. Analyze and inspect the measurements with their units.
  5. Export a result only with enough context to interpret it later.

At least one detected voiced second is needed for a pitch report. A microphone can capture sound without producing enough reliable repeating pitch information.

Natural speech and a sustained vowel are different tasks. Do not compare them as though only the person’s voice changed.

Read pitch separately from spectral features

Median fundamental is the middle retained frequency. The 5th–95th-percentile span describes a central portion of detected pitches rather than your full singing range.

Median absolute pitch deviation is the typical absolute cents distance from the sample’s own median. It is not error from a chosen melody note.

Spectral centroid is a magnitude-weighted frequency center. Two recordings can have similar fundamental pitch but different centroids because of articulation, recording setup or spectral content.

FeatureInterpretation
Fundamental pitchDetected repeating rate in hertz
Pitch deviationMovement around the sample median
Spectral centroidWeighted spectral frequency center
Band proportionsEnergy distribution in three defined areas
Digital levelSignal amplitude relative to full scale

The frequency bands cover approximately 50–250, 250–2,000 and 2,000–8,000 Hz where the input permits. A proportion is not a direct measure of warmth, confidence or intelligibility.

Interpret periodicity and levels carefully

Mean periodicity summarizes the frames that passed fundamental detection. It is conditional on that selection and is not a clinical harmonic-to-noise ratio, jitter or shimmer report.

RMS and sample peak are reported in dBFS, relative to digital full scale. They are not calibrated acoustic sound-pressure levels or a room-noise measurement.

A change from -24 to -18 dBFS in RMS is a +6 dB digital-level difference. It does not prove improved technique or a specific sound level at the microphone.

Understand the optional 0–10 score

Speech mode has no quality score. Held-note mode can report a custom consistency score after at least three detected voiced seconds.

The formula gives 60% weight to max(0, 1 minus median absolute pitch deviation divided by 100 cents), 30% to voiced time fraction and 10% to the non-clipping-frame fraction. The weighted sum is multiplied by ten and rounded to one decimal place.

For a hypothetical deviation of 30 cents, voiced fraction of 0.9 and clipping-frame fraction of 0.02, the calculation is 10 × (0.42 + 0.27 + 0.098) = 7.88, reported as 7.9.

That is a defined practice formula, not a validated rating of talent or attractiveness. Natural vibrato can lower it, while a steady wrong melody note can score highly because no external pitch target is supplied.

Compare controlled takes

Choose Keep as take A after a useful result. A later result in the same task mode shows B-minus-A changes in median frequency, centroid and digital RMS.

Keep the microphone, gain, distance, room and material alike. A changed microphone position can alter the spectral balance without demonstrating a change in voice production.

Take A is a memory-only measurement snapshot, not a saved voice recording. Reset clears the working measurements and selected file.

Prepare a suitable file

Files must be at most 20 MB and 120 seconds, decode as mono or stereo and fit the twelve-million-sample and frame limits. Codec support depends on the browser.

Stereo channels are averaged for analysis. Opposite-phase material can cancel, and music or effects in the source become part of the measured signal. The tool does not separate a singer from accompaniment.

Microphone mode requires a secure page, permission and AudioWorklet support. Do not assume identical behavior across every phone, browser or input device.

Choose a narrower test when useful

The Pitch Accuracy Test compares singing with an explicit target. The Voice Hz Test offers a simpler timed frequency summary using its own percentile method.

The Vocal Range Test establishes comfortable singing endpoints. The Singer Comparison Tool compares those intervals with reported profiles, without voice-identity recognition.

Export measurements without uploading audio

Copy the measurements, download scalar CSV or save the fuller JSON including band information. These are data exports, not playable recordings.

Live input and selected files are processed locally. The tool does not upload audio, create a public rating page or keep a permanent results account. Stop input and save useful measurements before resetting.

Frequently asked questions

Does this rate my singing with AI?

No trained model judges the performance. The optional score covers a limited held-note consistency task.

Why is the page named AI Voice Analysis?

That is its existing name. The current implementation is conventional local signal analysis, with the method and limits described here.

Can it tell whether my voice sounds good?

No. Pitch and spectral features do not establish an objective aesthetic or talent rating.

Why did I get measurements without a score?

Speech never receives a quality score. Held-note scoring also needs at least three detected voiced seconds.

Does it diagnose vocal health or recognize identity?

No. Those conclusions are outside the measurements provided.